| Unshielded Twisted Pair Category 6 cable (4 pairs,HSYV-6,HSYZ-6 Series)
Characteristics Transmission rate up to 250MHZ Used as cabling among the cross-connecting box and the communication output end of the operation area or between main distribution frames. Support 10 BASE-T,ISON,100BASE-T4/TX(Fast Ethermet),4/16Mbps signaling loop (IEEE802.5),100Mbps TP-PMD,ATM52/155Mbps
Structure Solid Bare Copper 23 AWG(0.573mm) PE Insulation,twisted,4pairs FR PVC or LSNHP steathed (The corlor of the sheath is normaliy grey,but can be assigned by the users),inside is filled with cross groove.
Standard NATIONAL STAND YD/T 1019-2001 INTERNATIO NAL ISO/IEC 11801 USA ANSI/TIA/EIA-568B
Tcchnology Index
|
频率Frepuency
|
特性阻抗Impedance |
衰减 近端串音衰减 等电平远端串音衰减 图波损耗
Attenuation Next ELFEXT RL |
|
Mhz |
O
- |
dB/100m
≤ |
dB/100m
≥ |
dB/100m
≥ |
dB
≥ |
|
1 |
100±15
|
1.9 |
74 |
68 |
20.0 |
|
4 |
3.7 |
65 |
56 |
23.0 |
|
10 |
5.9 |
59 |
48 |
25.0 |
|
16 |
7.5 |
56 |
44 |
25.0 |
|
20 |
8.4 |
55 |
42 |
25.0 |
|
31.25 |
10.6 |
52 |
38 |
23.6 |
|
62.5 |
15.4 |
47 |
32 |
21.5 |
|
100 |
19.8 |
44 |
22 |
20.1 |
|
200 |
29.0 |
40 |
22 |
18.0 |
|
250 |
32.8 |
38 |
20 |
17.3 |
Note: above reference values are all on the measurement by scanning frequency. |